D.P.X.MOUNTANT For Microscopy |
Synonyms : |
SECTION 1: Identification of the substance/mixture and of the company/undertaking |
|||
---|---|---|---|
1.1 Product identifier |
|||
Chemical Name : | D.P.X. MOUNTANT (for microscopy) | ||
Catalogue No. : | AL1964 | Product form : | Mixture |
CAS Number : | 130-12-2 | EC Number : | |
Grade : | EC Index Number : | ||
Chemical Formula : | HSN Code : | 38220090 | |
Synonyms : | |||
Chemical Structure : | |||
1.2 Relevant identified uses of the substance or mixture and uses advised against |
|||
Use of the substance/mixture : | Industrial For professional use only | ||
Uses advised against : | No additional information available | ||
1.3 Details of the supplier of the safety data sheet |
|||
Company identification : | Address:- 102, B wing, Savgan Heights, RTO Lane, Andheri (W), Mumbai-400 053 Maharashtra, India. |
||
1.4 Emergency Contact Details |
|||
Phone / e-Mail : | Phone : +91 22 26317055 Mobile : +91 9820385757 e-mail : info@alphachemika.co.in |
SECTION 2: Hazards identification |
|
---|---|
2.1 Classification of the substance or mixture |
|
Classification according to Regulation (EC) No. 1272/2008 [CLP] | |
Not classified see section 16 | |
Adverse physicochemical, human health and environmental effects | |
No additional information available | |
2.2 Label elements |
|
Labelling according to Regulation (EC) No. 1272/2008 [CLP] | |
Hazard pictograms (CLP) : | GHS02 GHS07 GHS08 GHS09 |
Signal word (CLP) : | Danger |
Hazard statements (CLP) : | H226 - Flammable liquid and vapour. H312+H332 - Harmful in contact with skin or if inhaled H315 - Causes skin irritation. H360Df - May damage the unborn child. Suspected of damaging fertility. H400 - Very toxic to aquatic life. |
Precautionary statements (CLP) : | P201 - Obtain special instructions before use. P273 - Avoid release to the environment. P280 - Wear protective gloves, protective clothing, eye protection, face protection. P308+P313 - IF exposed or concerned: Get medical advice/attention. |
2.3 Other hazards |
|
Other hazards : | No additional information available |
SECTION 3: Composition/information on ingredients |
|||
---|---|---|---|
3.1. Substance |
|||
Not applicable | |||
CAS No. : | 130-12-2 | ||
3.2. Mixture |
|||
Name | Product identifier | % | Classification according to Regulation (EC) No. 1272/2008 [CLP] |
Xylene | (CAS-No.) 1330-20-7 (EC-No.) 215-535-7 (EC Index-No.) 601-022-00-9 | 50 - 75 | Flam. Liq. 3, H226 Acute Tox. 4 (Dermal), H312 Acute Tox. 4 (Inhalation), H332 Skin Irrit. 2, H315 STOT SE 3, H335 |
TRICRESYL PHOSPHATE | (CAS-No.) 1330-78-5 | 10 - 15 | STOT SE 1, H370 Aquatic Chronic 2, H411 |
Full text of H-statements: see section 16 |
SECTION 4: First aid measures |
|
---|---|
4.1 Description of first aid measures |
|
First-aid measures after inhalation : | Remove person to fresh air and keep comfortable for breathing. Call a POISON CENTER/doctor if you feel unwell. |
First-aid measures after skin contact : | Wash with plenty of water/…. Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse. Get immediate medical advice/attention. |
First-aid measures after eye contact : | Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical advice/attention. |
First-aid measures after ingestion : | Rinse mouth. Do not induce vomiting. Get medical advice/attention. |
4.2 Most important symptoms and effects, both acute and delayed |
|
Symptoms relating to use : | Symptoms/effects : Suspected of damaging fertility. May damage the unborn child. Symptoms/effects after inhalation : May cause respiratory irritation. Symptoms/effects after skin contact : Harmful in contact with skin. Causes skin irritation. |
4.3 Indication of any immediate medical attention and special treatment needed |
|
General information : | Treat symptomatically. |
SECTION 5: Fire-fighting measures |
|
---|---|
5.1 Extinguishing media |
|
Suitable extinguishing media : | Carbon dioxide. Dry powder. Foam. Water spray. |
Unsuitable extinguishing media : | Do not use a heavy water stream. |
5.2 Special hazards arising from the substance or mixture |
|
Fire hazard : | Flammable liquid and vapour. |
Explosion hazard : | May form flammable/explosive vapour-air mixture. |
5.3 Advice for firefighters |
|
Protection during firefighting : | Do not enter fire area without proper protective equipment, including respiratory protection. |
SECTION 6: Accidental release measures |
|
---|---|
6.1 Personal precautions, protective equipment and emergency procedures |
|
General measures : | Remove ignition sources. No open flames. No smoking. Use special care to avoid static electric charges. |
6.1.1. For non-emergency personnel |
|
Emergency procedures : | Evacuate unnecessary personnel. |
6.1.2. For emergency responders |
|
Protective equipment | Use personal protective equipment as required |
Emergency procedures | Ventilate area. |
6.2 Environmental precautions |
|
Avoid release to the environment. | |
6.3 Methods and material for containment and cleaning up |
|
Methods for cleaning up : | Collect spillage. On land, sweep or shovel into suitable containers. |
6.4 Reference to other sections |
|
Reference : | No additional information available |
SECTION 7: Handling and storage |
|
---|---|
7.1 Precautions for safe handling |
|
Precautions for safe handling : | Avoid contact with skin and eyes. Do not breathe vapours. Provide good ventilation in process area to prevent formation of vapour. Keep away from sources of ignition - No smoking. Use only non-sparking tools. |
Hygiene measures : | Do not eat, drink or smoke when using this product. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work. |
7.2 Conditions for safe storage, including any incompatibilities |
|
Technical measures : | Proper grounding procedures to avoid static electricity should be followed. Use explosion-proof electrical/ventilating/lighting equipment. |
Storage conditions : | Keep in fireproof place. Keep container tightly closed. |
7.3 Specific end use(s) |
|
No additional information available |
SECTION 8: Exposure controls/personal protection |
|
---|---|
8.1 Control parameters |
|
No additional information available | |
8.2 Exposure controls |
|
Hand protection : | Protective gloves |
Eye protection : | Chemical goggles or safety glasses |
Skin and body protection : | Wear suitable protective clothing |
Respiratory protection : | [In case of inadequate ventilation] wear respiratory protection. |
SECTION 9: Physical and chemical properties |
|
---|---|
9.1 Information on basic physical and chemical properties |
|
Physical state : | Liquid Colour |
Colour : | Clear Colorless. |
Odour : | aromatic. |
Odour threshold : | No data available |
pH value : | 6 - 7 |
Relative evaporation rate (butylacetate=1) : | No data available |
Melting point : | No data available |
Freezing point : | No data available |
Boiling point : | No data available |
Flash point : | 24 °C |
Auto-ignition temperature : | 527 |
Decomposition temperature : | No data available |
Flammability (solid, gas) : | Flammable |
Vapour pressure : | No data available |
Relative vapour density at 20°C : | No data available |
Solubility : | No data available |
Log Pow : | No data available |
Viscosity, kinematic : | No data available |
Viscosity, dynamic : | No data available |
Explosive properties : | No data available |
Oxidising properties : | No data available |
Explosive limits : | No data available |
9.2 Other information |
|
No additional information available |
SECTION 10: Stability and reactivity |
|
---|---|
10.1 Reactivity |
|
No additional information available | |
10.2 Chemical stability |
|
Stable under normal conditions. | |
10.3 Possibility of hazardous reactions |
|
No additional information available | |
10.4 Conditions to avoid |
|
Open flame. Heat. Sparks. | |
10.5 Incompatible materials |
|
No additional information available | |
10.6 Hazardous decomposition products |
|
No additional information available |
SECTION 11: Toxicological information |
|
---|---|
11.1 Information on toxicological effects |
|
Acute toxicity : | Dermal: Harmful in contact with skin. Inhalation: Harmful if inhaled. ATE CLP (dermal) 1100 mg/kg bodyweight ATE CLP (gases) 4500 ppmv/4h ATE CLP (vapours) 11 mg/l/4h ATE CLP (dust,mist) 1.5 mg/l/4h |
Skin corrosion/irritation : | Causes skin irritation. pH: 6 - 7 |
Serious eye damage/irritation : | Not classified pH: 6 - 7 |
Respiratory or skin sensitisation : | Not classified |
Germ cell mutagenicity : | Not classified |
Carcinogenicity : | Not classified |
STOT-single exposure : | Not classified |
STOT-repeated exposure : | Not classified |
SECTION 12: Ecological information |
|
---|---|
12.1 Toxicity |
|
Toxicity information : | No additional information available |
12.2 Persistence - degradability |
|
Persistence - degradability : | No additional information available |
12.3 Bioaccumulative potential |
|
Bioaccumulative potential : | No additional information available |
12.4 Mobility in soil |
|
Mobility in soil : | No additional information available |
12.5 Results of PBT and vPvB assessment |
|
No additional information available | |
12.6 Other adverse effects |
|
Environmental precautions : | No additional information available |
SECTION 13: Disposal considerations |
|
---|---|
13.1 Waste treatment methods |
|
Additional Info : | No additional information available |
SECTION 14: Transport information |
|
---|---|
In accordance with ADR / RID / IMDG / IATA / ADN | |
14.1. UN number |
|
UN-No. (ADR) : | 1307 |
UN-No. (IMDG) : | 1307 |
UN-No. (IATA) : | 1307 |
UN-No. (ADN) : | 1307 |
UN-No. (RID) : | 1307 |
14.2. UN proper shipping name |
|
Proper Shipping Name (ADR) : | XYLENES |
Proper Shipping Name (IMDG) : | XYLENES |
Proper Shipping Name (IATA) : | XYLENES |
Proper Shipping Name (ADN) : | XYLENES |
Proper Shipping Name (RID) : | XYLENES |
Transport document description (ADR) : | UN 1307, XYLENES, 3, II ENVIRONMENTALLY HAZARDOUS |
Transport document description (IMDG) : | UN 1307, XYLENES, 3, II ENVIRONMENTALLY HAZARDOUS |
Transport document description (IATA) : | UN 1307, XYLENES, 3, II ENVIRONMENTALLY HAZARDOUS |
Transport document description (ADN) : | UN 1307, XYLENES, 3, II ENVIRONMENTALLY HAZARDOUS |
Transport document description (RID) : | UN 1307, XYLENES, 3, II ENVIRONMENTALLY HAZARDOUS |
14.3. Transport hazard class(es) |
|
ADR | |
Transport hazard class(es) : | 3 |
Danger labels : | 3 |
IMDG | |
Transport hazard class(es) : | 3 |
Danger labels : | 3 |
IATA | |
Transport hazard class(es) : | 3 |
Danger labels : | 3 |
ADN | |
Transport hazard class(es) : | 3 |
Danger labels : | 3 |
RID | |
Transport hazard class(es) : | 3 |
Danger labels : | 3 |
14.4. Packing group |
|
Packing group (ADR) : | II |
Packing group (IMDG) : | II |
Packing group (IATA) : | II |
Packing group (ADN) : | II |
Packing group (RID) : | II |
14.5. Environmental hazards |
|
Dangerous for the environment : | Yes |
Marine pollutant : | Yes |
Other information : | No supplementary information available |
14.6. Special precautions for user |
|
- Overland transport | |
Classification code (ADR) : F1 Limited quantities (ADR) : 1l Excepted quantities (ADR) : E2 Packing instructions (ADR) : P001, IBC02, R001 Mixed packing provisions (ADR) : MP19 Portable tank and bulk container instructions (ADR) : T4 Portable tank and bulk container special provisions (ADR) : TP1 Tank code (ADR) : LGBF Vehicle for tank carriage : FL Transport category (ADR) : 2 Special provisions for carriage - Operation (ADR) : S2, S20 Hazard identification number (Kemler No.) : 33 Orange plates : Tunnel restriction code (ADR) : D/E EAC code : 3YE |
|
- Transport by sea | |
Limited quantities (IMDG) : 1 L Excepted quantities (IMDG) : E2 Packing instructions (IMDG) : P001 IBC packing instructions (IMDG) : IBC02 Tank instructions (IMDG) : T4 Tank special provisions (IMDG) : TP1 EmS-No. (Fire) : F-E EmS-No. (Spillage) : S-D Stowage category (IMDG) : B Flash point (IMDG) : 17°C to 23°C c.c. Properties and observations (IMDG) : Colourless liquids. Flashpoint: 17°C to 23°C c.c. Explosive limits: 1.1% to 7% Immiscible with water. |
|
- Air transport | |
PCA Excepted quantities (IATA) : E2 PCA Limited quantities (IATA) : Y341 PCA limited quantity max net quantity (IATA) : 1L PCA packing instructions (IATA) : 353 PCA max net quantity (IATA) : 5L CAO packing instructions (IATA) : 364 CAO max net quantity (IATA) : 60L Special provisions (IATA) : A3 ERG code (IATA) : 3L |
|
- Inland waterway transport | |
Classification code (ADN) : F1 Limited quantities (ADN) : 1 L Excepted quantities (ADN) : E2 Carriage permitted (ADN) : T Equipment required (ADN) : PP, EX, A Ventilation (ADN) : VE01 Number of blue cones/lights (ADN) : 1 |
|
- Rail transport | |
Classification code (RID) : F1 Limited quantities (RID) : 1L Excepted quantities (RID) : E2 Packing instructions (RID) : P001, IBC02, R001 Mixed packing provisions (RID) : MP19 Portable tank and bulk container instructions (RID) : T4 Portable tank and bulk container special provisions (RID) : TP1 Tank codes for RID tanks (RID) : LGBF Transport category (RID) : 2 Colis express (express parcels) (RID) : CE7 Hazard identification number (RID) : 33 |
|
14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code |
|
Not applicable |
SECTION 15: Regulatory information |
---|
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture |
15.1.1 EU-Regulations : |
Contains no REACH substances with Annex XVII restrictions Contains no substance on the REACH candidate list Contains no REACH Annex XIV substances |
15.1.2. National regulations |
Germany |
12th Ordinance Implementing the Federal Immission Control Act - 12.BImSchV : Is not subject of the 12. BlmSchV (Hazardous Incident Ordinance) |
Netherlands |
SZW-lijst van kankerverwekkende stoffen : None of the components are listed SZW-lijst van mutagene stoffen : None of the components are listed NIET-limitatieve lijst van voor de voortplanting giftige stoffen- Borstvoeding : None of the components are listed NIET-limitatieve lijst van voor de voortplanting giftige stoffen- Vruchtbaarheid : None of the components are listed NIET-limitatieve lijst van voor de voortplanting giftige stoffen- Ontwikkeling : Xylene is listed |
Denmark |
Class for fire hazard : Class II-1 Store unit : 5 liter Classification remarks : R10 for the storage of flammable liquids must be followed Recommendations Danish Regulation : Young people below the age of 18 years are not allowed to use the product Pregnant/breastfeeding women working with the product must not be in direct contact with the product The requirements from the Danish Working Environment Authorities regarding work with carcinogens must be followed during use and disposal |
15.2 Chemical Safety Assessment |
No additional information available |
SECTION 16: Other Information |
||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|